The Bladder Scanner PBS V5.1 measures bladder volume and post void (PVR) residual volumes and makes assessment and care easy for male, female and paediatric patients.

 

Applications

Urology

Obstetrics & Gynecology

Anorectic

Rehabilitation

Emergency Departments

General Surgery

Community Medical Centers

Family Doctors

In-home medical

Emergency

Pediatric

Nursing homes

ICU

 

Features

Location prompts

Bladder border recognition

Portable

Light Weight

8.4” colour LCD TouchScreen

Real Time scanner

Non-invasive

3D Ultrasound Technology

User friendly software

Easy to operate

Stores patient images for review & records

USB Connectivity for data transfer to PC

Software upgrades via internet

Long life battery

Built-in smart calibrating program

Built in Printer

Accuracy: 85 – 95%

 

Scan Modes

Male

Female

Paediatric (Residual)

 

Scan Planes:

12 planes – quicker for scanning and calculation.

24 planes – better accuracy

 

Standard Configuration

Carry Case

Mobile Stand

Cradle

Printer

Battery

 

Optional

Bar Code Scanner

WiFi System

 

Specifications

Transducer frequency: 2.6 MHz

Scan method: 3D

Measurement method: Automatic measurement and Display

Real-time scanning and aiming

Result Display: Volume value, Max. measured value, Aiming Location, B mode Images (12/24 planes)

Outline the edge of the bladder for evaluating the effectiveness of the measurement

Accuracy: ±15%, ±15ml (0~150ml); ±10%, ±15ml (150~999ml) (on tissue-equivalent phantom)

Measurement Range: 0- 999ml

Scan depth: ≥180mm

Sway Angle: 95°±2°

Rotating Angle: 180°±2°

Storage Capacity: 100 cases

Case management: Store, Browse, Export

Patient ID: 12 digits

Printer: On-board Printer

Scan Mode: Male, Female, Paediatric

Display screen: 8.4" touch screen

Language: English; French; Germany; Spanish;

Power supply: Battery

Device Dimension: Approx. 310x260x50mm

Net weight: Approx. 2.1kg

 

Benefits

Accuracy: This bladder scanner has an 85 – 95% accuracy in comparison to conventional scanners that have a 60 – 70 % accuracy and requires a sonographer to calculate the measurements

 

Efficiency: The bladder scanner gives and automatic result with a 4-5 second scan time and does not require a sonographer as a trained nurse would be able to perform the task.

 

Outlines the bladder edge: The bladder scanner uses bladder edge recognition techniques on each B-mode images and outlines the edge with red lines making the task quick and easy to perform.

 

Prevents unnecessary catheterization and nosocomial infections: By measuring the bladder volume to decide whether catheterization is necessary, the hospital could save the expense of unnecessary catheterization and catheter-associated infections, improving the patients comfort and experience.

 

Improves Nursing Safety & Experience:  Be determining bladder volume for pre-assessment purposes.

 

TGA Registered: Yes

24 months (main unit) 12 months (probes)

 

For more information and to confirm specifications, please contact us to request a brochure.